S-2.1, r. 13 - Regulation respecting occupational health and safety

Full text
29. Prohibited usages: It is prohibited:
(1)  to use a portable ladder or a stepladder near an exposed electrical circuit, if it is made of metal or is metal-reinforced;
(2)  to use a portable ladder or a stepladder as a horizontal support;
(3)  to stand up on
(a)  the last 2 rungs of a portable ladder;
(b)  the top rung, on the pail shelf, on the rear section or on the top of a stepladder, except if it was so designed by the manufacturer;
(4)  to use the intermediate or upper section of a multiple-section ladder or of an extension ladder as the lower section, unless such use is authorized by the manufacturer.
O.C. 885-2001, s. 29; O.C. 502-2018, s. 6.
29. Prohibited usage: The top and the pail shelf of a stepladder shall never be used as a step.
O.C. 885-2001, s. 29.